Home/ Siemens wiring

Industrial Wireless MPG for Siemens Sinumerik CNC Controls

Siemens Sinumerik controls, from the compact 808D to production 828D and 5-axis 840D sl/one systems, demand high-accuracy manual positioning. Our Industrial Wireless MPG connects directly to Siemens PPU, MCP, or PP 72/48 I/O modules with zero software driver modifications.

See also our general compatibility page for Siemens Sinumerik controls.
Siemens logo, industrial wireless MPG for Siemens Sinumerik controls
Electrical specifications

Electrical specifications for Sinumerik controls

Two signal families land on two different modules: quadrature on the handwheel counter port, axis/rate selection on the MCP or distributed I/O.

  • 5V differential signals (RS422 line driver): 100 PPR quadrature channels (A, /A and B, /B) land on the controller's handwheel counter port.
  • 24V discrete PLC logic for selection: Axis selection (X, Y, Z, 4, 5) and increment multiplication (INC 1, INC 10, INC 100) are read as 24V active-high (PNP) digital inputs into the Machine Control Panel (MCP) or distributed I/O module.
Wiring pinout

Wireless receiver to Siemens Sinumerik PPU / MCP

Wiring pinout: wireless receiver to Siemens Sinumerik PPU / MCP
Receiver terminalSiemens signal functionTypical connection (PPU / PP 72/48)Electrical parameter
+5V / +24V VCCPower supply inputTerminal strip +5V DC or +24V DC railWide-range power input (5V–24V DC)
0V / GNDPower & signal groundTerminal strip 0V DC referenceCommon logic ground
Phase A+HW_A (Channel A)Handwheel port Pin 1 (A)5V RS422 differential square wave
Phase A-HW_/A (Inverted A)Handwheel port Pin 2 (/A)Inverted channel for common-mode rejection
Phase B+HW_B (Channel B)Handwheel port Pin 3 (B)5V RS422 differential 90° quadrature
Phase B-HW_/B (Inverted B)Handwheel port Pin 4 (/B)Inverted channel for common-mode rejection
Axis XDB77.DBX0.0 (Axis X)Digital input I x.0 (24V PNP)Logic high (+24V) activates X axis jog
Axis YDB77.DBX0.1 (Axis Y)Digital input I x.1 (24V PNP)Logic high (+24V) activates Y axis jog
Axis ZDB77.DBX0.2 (Axis Z)Digital input I x.2 (24V PNP)Logic high (+24V) activates Z axis jog
Axis 4 / 5DB77.DBX0.3 (Axis 4)Digital input I x.3 (24V PNP)Selects 4th/5th rotary axes
INC 1DB77.DBX1.0 (x1)Digital input I x.4 (24V PNP)Sets 0.001 mm increment
INC 10DB77.DBX1.1 (x10)Digital input I x.5 (24V PNP)Sets 0.010 mm increment
INC 100DB77.DBX1.2 (x100)Digital input I x.6 (24V PNP)Sets 0.100 mm increment
Safety E-stopEmergency loopSafety Integrated stringDual dry contacts open within 100 ms on link drop
Siemens wiring varies by machine: confirm yours free
Send your Sinumerik model and we'll confirm the exact pin assignment before your unit ships.
Confirm my wiring
Related pages
Siemens compatibility overview Fanuc wiring Mitsubishi wiring Syntec wiring Fagor wiring Heidenhain wiring Wireless vs wired MPG
Siemens MPG quote

Send your Siemens model
and MPG port type

We ship the unit pre-configured for your pinout, ready in one working day.